As the latest innovation from C&D Emerging Energy, the GMC Inverter Charger is purpose-built to meet the growing demands of modern mobile power systems. Engineered for use in recreational vehicles, specialty vehicles, and marine applications, it delivers exceptional performance with high efficiency, strong surge capability, and intelligent multi-stage charging.The GMC inverter charger features seamless automatic switching between AC and DC systems, ensuring uninterrupted power supply. It also integrates a main battery charger and a CAN-BUS communication port, enabling advanced system monitoring and interactive control to meet a wide range of user requirements.Built to perform in harsh conditions, the unit operates reliably at temperatures up to 50°C, maintaining full power output without derating or interruption. Durable, intelligent, and versatile, the GMC inverter charger is the ideal solution for mobile and off-grid power applications.
MODEL | GMC 2000 | GMC 3000 | GMC 4000 | GMC 5000 | GMC 6000 |
Raled Power | 2000W | 3000W | 4000W | 5000W | 6000W |
INPUT | |||||
Voltage | 100V110V120VAC; 220/230V240VAC | ||||
Selectable Voltage Range | Wide Range: 75VAC-138VAC; 155VAC-275VAC (for home appliances) Narrow Range: 82VAC-138VAC: 165VAC-275VAC (for personal computer) |
||||
Frequency | 40-70Hz | 100/110V/120VAC(±5W); 220V/230V240VAC(±10V) | |||
OUTPUT | |||||
AC Voltage Regulation (Batt Mode) |
100/110/120VAC(±5W); 220/230/240VAC(±10V) | ||||
Surge PoAer | 4000VA | 9000VA | 12000VA | 15000VA | 18000VA |
Efficiency (Peak) | 88% | 91% | |||
Transher Time | <20ms | < 10ms | |||
Wave form | Pure sine wave | ||||
BATTERY | |||||
Battery Voltage | 12V/24V | 12V/24V/48V | 24V/48V | 24V/48V | 24V/48V |
Charge curent | 75A/35A | 75A/50A/25A | 75A/35A | 75A/45A | 75A/50A |
Fast Charge Voltage | 14.3VDC for 12V(*2 for 24V. *4 for 48V) | ||||
Float Charge Voltage | 13.7VDC for 12V(*2 for 24V. *4 for 48V) | ||||
Battery Low Voltage Alarm | 16.5VDC for 12V(*2 for 24V. *4 for 48V) | ||||
Over Voltage Protection | 10.5VDC for 12V(*2 for 24V. *4 for 48V) | ||||
Battery low Voltage Shutdown | 10.0VDC for 12V(*2 for 24V. *4 for 48V) | ||||
Protection | Over charging, Over temp, Over battery voltage, Over load, short-circult | ||||
Operating EnvironmentTemperature | 50℃ | ||||
Cooling | Intelligent Fan | ||||
Display | LCD | ||||
Specification Setting | By LCD: Charging current, battery type, input voltage, output frequency, wide and narrow of AC input voltage, power-saver model, AC priority or battery priority |
||||
PHYSICAL | |||||
Dimension. (D"V"H)mm | 532*257*185.5 | 617.5*345*199.5 | |||
Net weight (kg) | 15 | 25.2/24.6 | 34.4/33.8 | 37.9/38.2 | 41.6/40.5 |
ENVIRONMENT | |||||
Humidity | 5-95 Relative humidity (No-condensing) | ||||
Operating Temperature | -10°C-50°C | ||||
Storage Temperature | -10°C-60°C |
AS/NZS 4763:2011, UL458, LVD(EN60950)